Related Experiment Video
Updated: Aug 25, 2025

Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral
Chengquan Wang1,2,3, Zheng Qu4, Yonggang Shen5
1Department of Civil Engineering, Zhejiang University City College, Hangzhou 310015, China.
Abstract:
In order to improve the construction efficiency of piers and reduce the local damage of piers, concrete-filled steel tubes (CFST) are used to precast pier segments. Aiming at the problems of the poor integrity and insufficient energy dissipation capacity of dry joint segmental assembled piers, segmental assembled concrete-filled steel tubular piers with external replaceable energy dissipators are being developed. Based on the low cyclic test of a segmental assembled CFST pier, the finite element numerical simulation model of a CFST pier is established based on ABAQUS software, and the validity of the numerical model is verified by the experimental results. The effects of the section ratio, axial compression ratio, and initial prestress on the seismic performance of piers are studied through a pseudostatic analysis. The results show that an increase in the section ratio can improve the lateral bearing capacity and energy dissipation capacity of the pier. When the section ratio is increased to 4%, the energy dissipation capacity of a CFST pier is increased by 77.8% and the lateral bearing capacity is increased by 33.9% compared with a section ratio of 2%, but the residual displacement of the pier top also increases. With an increase in the axial compression ratio, the energy dissipation capacity of the pier is significantly improved; when the axial compression ratio is increased to 0.30, the energy dissipation capacity of CFST piers is increased by 27.5% compared with a section ratio of 0.05, the residual displacement of the pier top is reduced, and the self-resetting effect of the pier is improved. A change in the initial prestress has no effect on the energy dissipation capacity of piers. Finally, based on an analysis of mechanical theory, a formula of bending capacity suitable for this type of pier is proposed, and the error is within 10%.
More Related Videos
11:25A Millimeter Scale Flexural Testing System for Measuring the Mechanical Properties of Marine Sponge Spicules
Published on: October 11, 2017
07:37Full-field Strain Measurements for Microstructurally Small Fatigue Crack Propagation Using Digital Image Correlation Method
Published on: January 16, 2019
Related Concept Videos
Castigliano's Theorem: Problem Solving
Eccentric Loading
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
Cable Subjected to a Distributed Load
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Eccentric Axial Loading in a Plane of Symmetry