Related Experiment Video
Updated: Aug 25, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Modeling and Simulation of Mechanical Performance in Textile Structural Concrete Composites Reinforced with Basalt
Rajesh Kumar Mishra1, Bijoya Kumar Behera2, Vijay Chandan1
1Department of Material Science and Manufacturing Technology, Faculty of Engineering, Czech University of Life Sciences Prague, 16500 Prague, Czech Republic.
Abstract:
This investigation deals with the prediction of mechanical behavior in basalt-fiber-reinforced concrete using the finite element method (FEM). The use of fibers as reinforcement in concrete is a relatively new concept which results in several advantages over steel-reinforced concrete with respect to mechanical performance. Glass and polypropylene (PP) fibers have been extensively used for reinforcing concrete for decades, but basalt fibers have gained popularity in recent years due to their superior mechanical properties and compatibility with concrete. In this study, the mechanical properties of basalt-fiber-reinforced concrete are predicted using FEM analysis, and the model results are validated by conducting experiments. The effect of fiber-volume fraction on the selected mechanical performance of concrete is evaluated in detail. Significant improvement is observed when the loading is increased. There are superior mechanical properties, e.g., load bearing and strain energy in basalt-fiber-reinforced concrete as compared to conventional concrete slabs reinforced with gravel or stones. The results of the simulations are correlated with experimental samples and show a very high similarity. Basalt-fiber-reinforced concrete (BFRC) offers a lightweight construction material as compared to steel-fiber-reinforced concrete (SFRC). Further, the problem of corrosion is overcome by using this novel fiber material in concrete composites.
Related Concept Videos
Fiber Reinforced Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Reinforcements in Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Elasticity in Concrete

