The Effect of Physical Faults on a Three-Shaft Gas Turbine Performance at Full- and Part-Load Operation
Waleligne Molla Salilew1, Zainal Ambri Abdul Karim2, Tamiru Alemu Lemma1
1Mechanical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar 32610, Perak, Malaysia.
Abstract:
A gas path analysis approach of dynamic modelling was used to examine the gas turbine performance. This study presents an investigation of the effect of physical faults on the performance of a three-shaft gas turbine at full-load and part-load operation. A nonlinear steady state performance model was developed and validated. The datasheet from the engine manufacturer was used to gather the input and validation data. Some engineering judgement and optimization were used. Following validation of the engine performance model with the engine manufacturer data using physical fault and component health parameter relationships, physical faults were implanted into the performance model to evaluate the performance characteristics of the gas turbine at degradation state at full- and part-load operation. The impact of erosion and fouling on the gas turbine output parameters, component measurement parameters, and the impact of degraded components on another primary component of the engine have been investigated. The simulation results show that the deviation in the output parameters and component isentropic efficiency due to compressor fouling and erosion is linear with the load variation, but it is almost nonlinear for the downstream components. The results are discussed following the plots.
More Related Videos
10:03Uncoupling Coriolis Force and Rotating Buoyancy Effects on Full-Field Heat Transfer Properties of a Rotating Channel
Published on: October 5, 2018
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Power System Three-Phase Short Circuits
Turbine-Governor Control
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Transmission Shafts: Problem Solving
Next, use bending moment diagrams for the shaft to...
Thin-Walled Hollow Shafts
Design of Transmission Shafts - Stress Analysis