A Low-Cost, Low-Power Water Velocity Sensor Utilizing Acoustic Doppler Measurement
Stephen Catsamas1, Baiqian Shi1, Boris Deletic1
1BoSL Water Monitoring and Control, Department of Civil Engineering, Monash University, Melbourne, VIC 3800, Australia.
Abstract:
Current commercial sensors to monitor water flow velocities are expensive, bulky, and require significant effort to install. Low-cost sensors open the possibility of monitoring storm and waste water systems at a much greater spatial and temporal resolution without prohibitive costs and resource investment. To aid in this, this work developed a low-cost, low-power velocity sensor based on acoustic Doppler velocimetry. The sensor, costing less than 50 USD is open-source, open-hardware, compact, and easily interfaceable to a wide range of data-logging systems. A freely available sensor design at this price point does not currently exist, and its novelty is in enabling high-resolution real-time monitoring schemes. The design is capable of measuring water velocities up to 1200 mm/s. The sensor is characterised and then verified in an in-field long-term test. Finally, the data from this test are then used to evaluate the performance of the sensor in a real-world scenario. The analysis concludes that the sensor is capable of effectively measuring water velocity.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Deriving the Speed of Sound in a Liquid
The speed of sound in fluids can be derived by considering a mechanical wave...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pipe Flowrate Measurement: Problem Solving