Real-Time Non-Contact Millimeter Wave Radar-Based Vital Sign Detection
Zhiqiang Gao1, Luqman Ali2, Cong Wang2
1School of Astronautics, Harbin Institute of Technology, Harbin 150001, China.
Abstract:
In this paper, the extraction of the life activity spectrum based on the millimeter (mm) wave radar is designed to realize the detection of target objects and the threshold trigger module. The maximum likelihood estimation method is selected to complete the design of the average early warning probability trigger function. The threshold trigger module is designed for the echo signal of static objects in the echo signal. It will interfere with the extraction of Doppler frequency shift results. The moving target detection method is selected, and the filter is designed. The static clutter interference is filtered without affecting the phase difference between the detection sequences, and the highlight target signal is improved. The frequency and displacement of thoracic movement are used as the detection data. Through the Fourier transform calculation of the sequence, the spectrum value is extracted within the estimated range of the heartbeat and respiration spectrum, and the heartbeat and respiration signals are picked up. The proposed design uses Modelsim and Quartus for CO-simulation to complete the simulation verification of the function, extract the number of logical units occupied by computing resources, and verify the algorithm with the vital signs experiment. The heartbeat and respiration were detected using the sports bracelet; the relative errors of heartbeat detection were 0-6.3%, the respiration detection was 0-9.5%, and the relative errors of heartbeat detection were overwhelmingly less than 5%.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...