Background:
The purpose of the study is to evaluate reoperation rate and its relationship to preoperative mechanical axis of rotating-hinge TKA used as the primary implant in complex knees.
Methods:
Patients subjected to primary TKA with a rotating-hinge knee prosthesis due to primary osteoarthritis between 2010 and 2019 were retrospectively reviewed. Preoperative mechanical axis was measured using the last preoperative telemetry x-ray image. Preoperative axis was classified according to the type of deformity (varus or valgus) and its magnitude (0-15°, 16-25° or >25°). Reoperation rate (with or without implant removal) was the primary outcome of the current study. We studied if the preoperative mechanical axis (either varus-valgus, or magnitude of malalignment) was related to implant survival rate.
Results:
Forty-two patients were included in the study. Mean follow-up was 51.42 ± 31.88 months. The 83.3% of patients presented a valgus axis while the 16.7% presented a varus axis. Need of reoperation occurred in eight patients (19.0%). However, no patients (0%) required implant removal with revision TKA. No association was seen between the preoperative mechanical axis and risk of reoperation (p = 0.16).
Conclusion:
In selected situations that do not permit less constrained implants, primary rotating-hinge arthroplasty could be a good alternative. Risk of reoperation does not seem to depend upon the preoperative mechanical axis when using a rotating-hinge knee prosthesis for primary arthroplasty in non-tumoral complex knees.