Programmable Y-Shaped Probes with Proximity Bivalent Recognition for Rapid Electrochemiluminescence Response of Acute
Xian-Ming Guo1, Mei-Ling Zhao1, Wen-Bin Liang1
1Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
Abstract:
Herein, an exogenous luminophore-free and disposable electrochemiluminescence (ECL) biosensor was established for rapid response of acute myocardial infarction (AMI) using programmable Y-shaped probes (Y-probes) with proximity bivalent recognition. Specifically, the indium tin oxide thin film coated glass electrode (ITO) was modified with urchin-like porous TiO2 microspheres (pTiO2 MSs), which could achieve strong and stable ECL in S2O82- solution due to the dual promoting effect of the coreaction accelerator pTiO2 MSs, exhibiting 2.7-fold higher ECL intensity in comparison with that of bare ITO. Moreover, the Y-probes as bivalent recognition elements containing two kinds of cardiac troponin I (cTnI, a biomarker of AMI) aptamers and a linker labeled with ferrocene (L-Fc) were designed to export a "signal off" mode. When the target cTnI was in the proximity of the Y-probes, the L-Fc was separated from the electrode surface due to the proximity recognition of cTnI and its aptamers, achieving the highly effective recovery of ECL, which allowed for a much more rapid detection of cTnI than the sandwich-type immunoassay. As a proof of concept, an exogenous luminophore-free and disposable ECL platform for rapid and sensitive monitoring of cTnI was obtained and displayed a desired linear range from 100 fg mL-1 to 100 ng mL-1 with a limit of detection (LOD) of 30.1 fg mL-1, which can be ingeniously expanded as a portable home tester with ECL biosensors developments.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
08:20Time-Resolved In Vivo Measurement of Neuropeptide Dynamics by Capacitive Immunoprobe in Porcine Heart
Published on: May 19, 2022
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...