Flexible Loading Pattern Approach in Overkill Steam Sterilization Based on the Physical Properties of Steam and

Arnan Ben-David1

  • 110AR - Sterile Engineering Solutions, 7 Yona Volach St., Rosh Haain, Israel arnan@10ar.co.il.

Related Concept Videos

Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
20.6K
Methods of Sterilization II: Chemical Methods01:30

Methods of Sterilization II: Chemical Methods

In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
6.8K
Physical Methods for Controlling Microbial Growth: Temperature01:23

Physical Methods for Controlling Microbial Growth: Temperature

Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
200
Saint-Venant's Principle01:18

Saint-Venant's Principle

The principle of Saint-Venant postulates that the stress distribution within a structural member does not rely on the precise method of load application except in the vicinity of the load application points. Consider a scenario where loads are centrally applied on two plates. In this case, the plates move toward each other without any rotation. This movement causes the member to contract in length and expand in width and thickness. Uniform deformation across all elements and maintaining...
793
Residual Stresses in Bending01:18

Residual Stresses in Bending

In the study of elastoplastic members subjected to bending moments, understanding the loading and unloading phases is crucial for assessing material behavior and structural integrity. During the loading phase, as the bending moment increases, the material initially responds elastically, adhering to Hooke's Law, where stress is directly proportional to strain. When the load exceeds the yield strength, plastic deformation occurs, resulting in permanent strain and deformation that remains even...
239
Physical Methods for Controlling Microbial Growth: Radiation and Filtration01:26

Physical Methods for Controlling Microbial Growth: Radiation and Filtration

Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
194