Related Experiment Video
Updated: Aug 25, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Discriminative strain and temperature sensing using a ring-hyperbolic tangent fiber sensor
Abstract:
Brillouin fiber sensors have demonstrated strong capability in discriminative and high-sensitivity multiparameter measurements. In this study, we proposed and numerically investigated novel ring core fiber-based stimulated Brillouin scattering for the simultaneous measurement of temperature and strain. The novel fiber, referred to as ring hyperbolic tangent (R-HTAN) fiber, is characterized by a shape parameter (α) that controls the optical refractive index and longitudinal acoustic velocity profiles. Numerical modal simulations indicated that the Brillouin gain spectrum contained multiple widely spaced and high-gain peaks, which were attributed to the strong interaction between the optical linearly polarized mode (i.e., LP0,1 as a pump wave) and multiple high-order longitudinal acoustic modes. The designed R-HTAN fiber enabled the discriminative sensing of temperature and strain with levels that clearly surpassed values recently reported in the literature. In case of straight R-HTAN fiber (α = 0), the maximum C(α=0)T and C(α=0)ε are 1.928 MHz/ ∘C and 0.087 MHz, respectively. In case of graded R-HTAN fiber (α = 1), the maximum C(α=1)T and C(α=1)ε are 1.872 MHz/ ∘C and 0.0842 MHz/μɛ, respectively. The errors associated with temperature measurements (maximum δT(α=0) = 0.0846 ∘C and maximum δT(α=1) = 7.4184 ∘C) and strain measurements (maximum δɛ(α=0) = 0.7250 μɛ and maximum δɛ(α=1) = 7.4184 μɛ) demonstrated that the proposed fiber could be a promising candidate for next-generation Brillouin sensing systems for enabling temperature and strain discrimination.
Related Concept Videos
Thermal Strain
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Design Example: Strain Gauge Bridge or Wheatstone Bridge

