Related Experiment Video
Updated: Jun 25, 2026

Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
Biosensor Characterization from Cratylia mollis Seed Lectin (Cramoll)-MOF and Specific Carbohydrate Interactions in
Maryana Hermínio de Carvalho1,2, Hallysson Douglas Andrade de Araújo1, Renata Pereira da Silva2
1Departamento de Bioquímica, Centro de Biociências, CB, Universidade Federal de Pernambuco, Avenida Prof. Moraes Rego, 1235, Cidade Universitária, 50670-420, Recife-PE, Brazil.
Abstract:
Biosensors are small devices known for their selectivity, high specificity and sensitivity to the respective analyte, at low concentrations. We developed an electrochemical biosensor using the crystalline polymer MOF-[Cu3 (BTC)2 (H2 O)2 ]n to characterize Cratylia mollis seed lectin (Cramoll) and its interaction with free carbohydrate (glucose) and carbohydrates on the surface of rabbit erythrocytes. The electrochemical potentials presented by the exponential curves that vary from 96 to 142 mV in relation to concentrations of 10 to 20 mM of glucose are decisive for the use of the system containing gold electrode/MOF/Cramoll for the characterization of biological models due to its high sensitivity. As well as the kinetic behavior presented in the cyclic voltammograms, with a cathodic current response of 0.000 3 A for a glucose concentration of 15 mM. These results were due to the high specificity of Cramoll under these conditions, promoting stability of surface charges at the Cramoll/electrode interface. This phenomenon facilitates the monitoring of the interaction with free glucose present in the electrolyte medium by potentiometric and amperometric methods and with carbohydrates present on the surface of rabbit erythrocytes through the potentiometric method. Through scanning electron microscopy (SEM) it was possible to observe Cramoll immobilized on the MOF surface, proving the specificity of the ligand (glucose-lectin) through the morphological lectin changes in this process. This electrochemical model, Cramoll/MOF biosensor, is effective for evaluating free lectin/carbohydrate or in the erythrocyte membrane.
More Related Videos
08:06The Use of a β-lactamase-based Conductimetric Biosensor Assay to Detect Biomolecular Interactions
Published on: February 1, 2018
09:39Exploring Biomolecular Interaction Between the Molecular Chaperone Hsp90 and Its Client Protein Kinase Cdc37 using Field-Effect Biosensing Technology
Published on: March 31, 2022