An ultra-performance LC-MS/MS method for determination of JRF103 in human plasma: application in first in-patient

Ying Jin1, Xiangjie Di1, Lisha Fu1

  • 1Clinical Trial Center/National Medical Products Administration Key Laboratory for Clinical Research and Evaluation of Innovative Drug, West China Hospital of Sichuan University, Chengdu, 610041, China.

Bioanalysis
|October 17, 2022
PubMed

Background: JRF103, a novel pan-HER inhibitor, has shown potent activity against HER1, HER2, HER4 and EGFR in vitro. To support its first in-patient trial, a sensitive and rapid method was developed and validated using ultra-performance LC-MS/MS. Materials & methods: JRF103 was extracted from plasma using protein precipitation. Extracts were subjected to ultra-performance LC-MS/MS with electrospray ionization. Results: Separation of analyte was achieved using a 1.7-μm C18 column (2.1 × 50-mm internal diameter) with a gradient elution. The developed method was fully validated following the international guides. Conclusion: The developed method was sensitive, specific and suitable for measuring JRF103 concentration in patients with advanced solid tumors in the first in-patient study of JRF103.

Related Concept Videos

High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.5K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
576
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
884