Related Experiment Video
Updated: Aug 25, 2025

Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022
Point-of-Care Noninvasive Technology for Pediatric Dehydration Assessment
David C Sheridan1, Guillermo A Kohn-Loncarica2, Pedro Nunez2
1From the Department of Emergency Medicine, Oregon Health and Science University, Portland, OR.
Objective:
Dehydration is a commonly encountered problem worldwide. Current clinical assessment is limited by subjectivity and limited provider training with children. The objective of this study is to investigate a new noninvasive, point-of-care technology that measures capillary refill combined with patient factors to accurately diagnose dehydration.
Methods:
This is a prospective observational study at a tertiary care children's hospital in Buenos Aires, Argentina. Patients were eligible if younger than 10 years who presented to the emergency department with vomiting and/or diarrhea whom the triage nurse deems to be potentially dehydrated. Patients had the digital capillary refill device done on presentation in addition to standard of care vital signs and weight. Patients had serial weights measured on hospital scales throughout their stay. The primary outcome was dehydration, which was calculated as a percent change in weight from admission to discharge.
Results:
Seventy-six children were enrolled in the study with 56 included in the final analysis. A stepwise forward method selection chose malnutrition, temperature, and systolic blood pressure for the multivariable model. The area under the curve for the final model was fair (0.7431). To further look into the utility of such a device in the home setting where blood pressure is not available often, we reran the model without systolic blood pressure. The area under the curve for the final model was 0.7269.
Conclusions:
The digital capillary refill point-of-care device combined with readily available patient-specific factors may improve the ability to detect pediatric dehydration and facilitate earlier treatment or transfer to higher levels of care.
Related Concept Videos
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...