Related Experiment Video
Updated: Aug 25, 2025

13:08
Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012
19.0K
Selective human factor VIII activity measurement after analytical in-line purification
Andrea Engelmaier1, Gerald Schrenk1, Manfred Billwein1
1Analytical Development, Pharmaceutical Science Baxalta Innovations GmbH, Part of Takeda Vienna Austria.
Research and Practice in Thrombosis and Haemostasis
|October 18, 2022
Summary
A new antibody-based assay accurately measures human factor VIII (FVIII) activity. This method overcomes challenges from animal FVIII, additives, and antibodies, ensuring reliable FVIII concentrate analysis.
Area of Science:
- Biochemistry
- Pharmacology
- Analytical Chemistry
Background:
- Measuring factor VIII (FVIII) activity is crucial for coagulation FVIII concentrates.
- Assays can be biased by nonhuman FVIII, manufacturing additives, and FVIII-mimicking antibodies.
- Accurate FVIII measurement is vital for pharmacokinetic studies and quality control.
Purpose of the Study:
- To develop a selective and sensitive assay for human FVIII activity.
- To overcome interference from animal plasma, additives, and antibodies.
- To ensure accurate FVIII measurement in complex biological matrices.
Main Methods:
- Developed an antibody-based chromogenic assay using a plate-bound monoclonal anti-FVIII antibody for specific human FVIII capture.
- Utilized a human reference plasma for calibration curve construction.
- Validated the assay in cynomolgus monkey plasma with solvent/detergent treatment and emicizumab presence.
Main Results:
- The assay demonstrated good accuracy and reproducibility with a calibration curve from 3.03 to 97.0 mIU FVIII/ml.
- Both B domain-deleted and full-length FVIII showed similar responses.
- Spiked human FVIII recovery in monkey plasma was 102.7%, with no activity detected in native monkey plasma or from additives/emicizumab.
Conclusions:
- The developed assay selectively and sensitively measures human FVIII activity.
- It effectively eliminates interference from endogenous nonhuman FVIII, manufacturing additives, and FVIII-mimicking antibodies.
- This antibody-based chromogenic assay provides a reliable method for FVIII activity quantification.