Related Experiment Video
Updated: Aug 25, 2025

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
Published on: February 4, 2018
Analysis of an inverse weak-value tiltmeter in the kilohertz regime
Abstract:
We present a follow-on experiment to the recent study from The University of Rochester [Opt. Lett.42, 2479 (2017)OPLEDP0146-959210.1364/OL.42.002479], which reported a new architecture for an inverse weak-value tiltmeter. We recreate the Rochester tiltmeter and specifically investigate mirror oscillations in the low-kilohertz frequency regime, which is relevant to certain potential applications, such as Coriolis vibratory gyroscopes. We find that the inverse weak-value amplification effect persists in this regime, although our measured noise floors are higher than those obtained in the Rochester experiment-approximately 2prad/Hz for mirror oscillation frequencies between 1 and 25 kHz.
More Related Videos
Related Concept Videos
Mass Analyzers: Common Types
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Factors Affecting Measurements
Amperometry: Overview
Inverting and Non-inverting OpAmps