Related Experiment Video
Updated: Aug 25, 2025

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
High quality of an absolute phase reconstruction for coherent digital holography with an enhanced anti-speckle deep
Abstract:
It is always a challenge how to overcome speckle noise interference in the phase reconstruction for coherent digital holography (CDH) and its application, as this issue has not been solved well so far. In this paper, we are proposing an enhanced anti-speckle deep neural unwrapping network (E-ASDNUN) approach to achieve high quality of absolute phase reconstruction for CDH. The method designs a special network-based noise filter and embeds it into a deep neural unwrapping network to enhance anti-noise capacity in the image feature recognition and extraction process. The numerical simulation and experimental test on the phase unwrapping reconstruction and the image quality evaluation under the noise circumstances show that the E-ASDNUN approach is very effective against the speckle noise in realizing the high quality of absolute phase reconstruction. Meanwhile, it also demonstrates much better robustness than the typical U-net neural network and the traditional phase unwrapping algorithms in reconstructing high wrapping densities and high noise levels of phase images. The E-ASDNUN approach is also examined and confirmed by measuring the same phase object using a commercial white light interferometry as a reference. The result is perfectly consistent with that obtained by the E-ASDNUN approach.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Reconstruction of Signal using Interpolation
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...