Related Experiment Video
Updated: Aug 24, 2025

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Electrochemical sensor for the detection of adrenaline at poly(crystal violet) modified electrode: optimization and
Saheed E Elugoke1,2, Omolola E Fayemi1,2, Abolanle S Adekunle3
1Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Private Bag X2046, Mmabatho 2735, South Africa.
Abstract:
Herein, we report the electropolymerization of crystal violet (CRV) on a bare glassy carbon electrode (GCE) for the detection of adrenaline (AD). Electropolymerization parameters such as electrolyte pH, scan rate and monomer concentrations were optimized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The characterization of CRV and poly(crystal violet) (PCV) was done using FT-IR, UV-visible spectroscopy and EIS. More importantly, the charge transfer resistance (Rct) and other EIS data recorded from the EIS of various forms of the poly(crystal violet) (PCV) modified glassy carbon electrode (GCE) in AD were used for identifying the best PCV modified electrode. Subsequent application of the electrode prepared at optimum conditions (PGCE) for AD detection using the square wave voltammetry (SWV) gave a limit of detection (LOD) of 2.86 μM over a linear range of 10.3-102.7 μM. This sensor also showed considerable stability, good AD recovery from the real sample (98.9%), and excellent reproducibility, making it a suitable analytical tool for AD detection at the micromolar level.
More Related Videos
09:33Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Potentiometry: Membrane Electrodes
Amperometry: Overview
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...