Ventricular-arterial coupling assessed by PWV/GLS ratio in hypertensive patients
G Stoichescu-Hogea1, F N Buleu, G Nicusor Pop
1Department of Cardiology, "Victor Babes" University of Medicine and Pharmacy, Timisoara, Romania. buleu.florina@gmail.com.
The PWV/GLS ratio effectively detects altered ventricular-arterial coupling in hypertensive patients, offering a new tool for monitoring cardiovascular health and treatment efficacy.
Area of Science:
- Cardiology
- Vascular Physiology
- Biomedical Engineering
Background:
- Ventricular-arterial coupling (VAC) is crucial for optimal cardiac work and cardiovascular performance.
- Hypertension significantly impacts the interaction between the left ventricle and arterial system.
- Assessing VAC is vital for understanding cardiovascular health in hypertensive individuals.
Purpose of the Study:
- To evaluate the utility of the pulse wave velocity (PWV) to global longitudinal strain (GLS) ratio in assessing ventricular-arterial coupling (VAC).
- To compare VAC parameters in hypertensive patients with and without coronary artery disease against healthy controls.
- To identify a predictive threshold for altered VAC using the PWV/GLS ratio.
Main Methods:
- Calculated the PWV/GLS ratio in 135 participants across three groups: hypertensive patients with coronary artery disease (HT+CAD), hypertensive patients (HT), and healthy controls (CON).
- Measured pulse wave velocity (PWV) as a marker of arterial stiffness and global longitudinal strain (GLS) as a marker of left ventricular function.
- Utilized Receiver Operating Characteristic (ROC) curve analysis to determine the diagnostic threshold for altered VAC.
Main Results:
- Significantly reduced GLS and elevated PWV were observed in both HT+CAD and HT groups compared to controls (p<0.001).
- The PWV/GLS ratio was significantly lower in hypertensive groups (HT+CAD and HT) versus controls (p<0.001), indicating impaired VAC.
- An ROC curve analysis identified a PWV/GLS ratio threshold of -0.054 for detecting altered VAC with an AUROC of 0.836.
Conclusions:
- The PWV/GLS ratio is a valuable tool for detecting altered ventricular-arterial coupling in hypertensive patients.
- This ratio holds potential for monitoring early multi-organ damage and evaluating antihypertensive medication efficacy.
- Further extensive prospective studies are warranted to validate these findings and clinical applications.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: