Association Between Device-Detected Sleep-Disordered Breathing and Implantable Defibrillator Therapy in Patients With
Andrea Mazza1, Maria Grazia Bendini1, Valter Bianchi2
1Cardiology Division, Santa Maria della Stella Hospital, Orvieto, Italy.
Background:
Sleep-disordered breathing is highly prevalent in heart failure (HF) and has been suggested as a risk factor for malignant ventricular arrhythmias. The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter-defibrillator (ICD) algorithm accurately identifies severe sleep apnea.
Objectives:
In the present analysis, the authors evaluated the association between ICD-detected sleep apnea and the incidence of appropriate ICD therapies in patients with HF.
Methods:
We enrolled 411 HF patients who had received an ICD endowed with an algorithm that calculates the RDI each night. In this analysis, the weekly mean RDI value was considered. The endpoint was the first appropriate ICD shock.
Results:
The median follow-up was 26 months (25th to 75th percentile: 16-35 months). During follow-up, 1 or more ICD shocks were documented in 58 (14%) patients. Patients with shocks were younger (age 66 ± 13 years vs 70 ± 10 years; P = 0.038), and had more frequently undergone implantation for secondary prevention (21% vs 10%; P = 0.026). The maximum RDI value calculated during the entire follow-up period did not differ between patients with and without shocks (55 ± 15 episodes/h vs 54 ± 14 episodes/h; P = 0.539). However, the ICD-detected RDI showed considerable variability during follow-up. The overall median of the weekly RDI was 33 episodes/h (25th to 75th percentile: 24-45 episodes/h). A time-dependent Cox regression model revealed that a continuously measured weekly mean RDI of ≥45 episodes/h was independently associated with shock occurrence (HR: 4.63; 95% CI: 2.54-8.43; P < 0.001), after correction for baseline confounders (age, secondary prevention).
Conclusions:
In HF patients, appropriate ICD shocks were more likely to be delivered during periods when patients exhibited more sleep-disordered breathing. (Arrhythmias Detection in a Real World Population [RHYTHM DETECT]; NCT02275637).
More Related Videos
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiopulmonary Resuscitation III: AED Use
Heart Failure VI: Adjunct Therapies
Sleep Apnea
The condition is more prevalent among...
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...