Related Experiment Video
Updated: Aug 24, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Existing Bowel Preparation Quality Scales Are Reliable in the Setting of Centralized Endoscopy Reading
Jurij Hanzel1,2,3, Michael Sey4,5, Christopher Ma3,6
1Department of Gastroenterology and Hepatology, Amsterdam UMC, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
Background:
Development of bowel preparation products has been based upon colon cleansing rating by a local endoscopist. It is unclear how bowel preparation scales perform when centrally evaluated.
Aims:
To evaluate the reliability of bowel preparation quality scales when assessed by central readers.
Methods:
Four central readers evaluated 52 videos in triplicate, 2 weeks apart, during the entire endoscopic procedure (insertion/withdrawal of the colonoscope) and exclusively on colonoscope withdrawal using the Boston Bowel Preparation Scale (BBPS), Chicago Bowel Preparation scale, Harefield Cleansing Scale, Ottawa Bowel Preparation Quality Scale (OBPQS), Aronchick score, a visual analogue scale, and additional items proposed in a modified Research and Development/University of California Los Angeles appropriateness process. Reliability was assessed with intraclass correlation coefficients.
Results:
Intraclass correlation coefficients (95% confidence interval) for inter-rater reliability of the quality scales ranged from 0.51 to 0.65 (consistent with moderate to substantial inter-rater reliability) during the entire procedure. Corresponding intraclass correlation coefficients for intra-rater reliability ranged from 0.69 to 0.77 (consistent with substantial intra-rater reliability). Reliability was highest in the right colon and lowest in the left colon. No differences were observed in reliability when assessed for the procedure overall (insertion/withdrawal) relative to assessment on withdrawal alone.
Conclusion:
All five bowel preparation quality scales had moderate to substantial inter-rater reliability. Panelists considered the Aronchick score too simplistic for clinical trials and recognized that assessment of residual fluid in the Ottawa Bowel Preparation Quality Scale was not amenable to central assessment.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
03:44Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: