Related Experiment Video
Updated: Aug 24, 2025

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Contactless skin perfusion monitoring with video cameras: tracking pharmacological vasoconstriction and vasodilation
M Harford1,2,3, M Villarroel2, J Jorge2
1Critical Care Research Group, Kadoorie Centre for Critical Care Research and Education, Nuffield Department of Clinical Neurosciences, University of Oxford, United Kingdom.
Abstract:
Objectives.Clinical assessment of skin perfusion informs prognosis in critically ill patients. Video camera monitoring could provide an objective, continuous method to monitor skin perfusion. In this prospective, interventional study of healthy volunteers, we tested whether video camera-derived photoplethysmography imaging and colour measurements could detect drug-induced skin perfusion changes.Approach.We monitored the lower limbs of 30 volunteers using video cameras while administering phenylephrine (a vasoconstrictor) and glyceryl trinitrate (a vasodilator). We report relative pixel intensity changes from baseline, as absolute values are sensitive to environmental factors. The primary outcome was the pre- to peak- infusion green channel amplitude change in the pulsatile PPGi waveform component. Secondary outcomes were pre-to-peak changes in the photoplethysmographic imaging waveform baseline, skin colour hue and skin colour saturation.Main results.The 30 participants had a median age of 29 years (IQR 25-34), sixteen (53%) were male. A 34.7% (p= 0.0001) mean decrease in the amplitude of the pulsatile photoplethysmographic imaging waveform occurred following phenylephrine infusion. A 30.7% (p= 0.000004) mean increase occurred following glyceryl trinitrate infusion. The photoplethysmographic imaging baseline decreased with phenylephrine by 2.1% (p= 0.000 02) and increased with glyceryl trinitrate by 0.5% (p= 0.026). Skin colour hue changed in opposite direction with phenylephrine (-0.0013,p= 0.0002) and glyceryl trinitrate (+0.0006,p= 0.019). Skin colour saturation decreased with phenylephrine by 0.0022 (p= 0.0002), with no significant change observed with glyceryl trinitrate (+0.0005,p= 0.21).Significance.Drug-induced vasoconstriction and vasodilation are associated with detectable changes in photoplethysmographic imaging waveform parameters and skin hue. Our findings suggest video cameras have great potential for continuous, contactless skin perfusion monitoring.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
06:50Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017