Related Experiment Video
Updated: Aug 24, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Transformer With Double Enhancement for Low-Dose CT Denoising
Abstract:
Increasingly serious health problems have made the usage of computed tomography surge. Therefore, algorithms for processing CT images are becoming more and more abundant. These algorithms can lessen the harm of cumulative radiation in CT technology for the patient while eliminating the noise of image caused by dose reduction. However, the mainstream CNN-based algorithms are inefficient when dealing with features in broad regions. Inspired by the large receptive field of transformer framework, this paper designs an end-to-end low-dose CT (LDCT) denoising network based on the transformer. The overall network contains a main branch and dual side branches. Specifically, the overlapping-free window-based self-attention transformer block is adopted on the main branch to realize image denoising. On the dual side branches, we propose double enhancement module to enrich edge, texture, and context information of LDCT images. Meanwhile, the receptive field of network is further enlarged after processing, which is helpful for building model's long-range dependencies. The outputs of the side branches are concatenated for enhancing information and generating high-quality CT images. In addition, to better train the network, we introduce a compound loss function including mean squared error (MSE), multi-scale perceptual (MSP), and Sobel-L1 (SL) to make the denoised image closer to the targeted norm-dose CT (NDCT) image. Lastly, we conducted experiments on two clinical datasets including abdomen, head, and chest LDCT images with 25%, 25%, and 10% of the full dose, respectively. The experimental results demonstrated that the proposed DEformer achieved better denoising performance than the existing algorithms.
More Related Videos
04:23A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Voltage Doubler Circuit