Development of a novel, label-free N-glycan method using charged aerosol detection
Ryan Knihtila1, Letha Chemmalil2, Pranoti Sawant3
1Tectonic Therapeutic, 490 Arsenal Way, Suite 210, Watertown, MA 02472, United States.
Summary
A new label-free method simplifies N-glycan analysis for monoclonal antibodies (mAbs), reducing preparation time and costs. This approach offers comparable results to traditional methods, validating its use in biopharmaceutical quality control.
Area of Science:
- Biochemistry
- Analytical Chemistry
- Biotechnology
Background:
- Monoclonal antibodies (mAbs) are crucial biotherapeutics, with N-linked glycans on their Fc region significantly impacting efficacy and half-life.
- Current methods for N-glycan analysis involve denaturation, enzymatic release (e.g., PNGase F), and fluorescent labeling, which are time-consuming and use hazardous reagents.
- These glycans are critical quality attributes requiring robust analytical methods for biopharmaceutical release testing.
Purpose of the Study:
- To develop and validate a novel, label-free method for the detection and quantification of N-glycans from monoclonal antibodies.
- To reduce sample preparation time, costs, and the use of toxic reagents in N-glycan analysis.
- To provide an alternative analytical approach for routine biopharmaceutical quality control.
Main Methods:
- N-glycans were analyzed using a label-free approach employing mixed-mode PGC chromatography.
- Detection of non-derivatized glycans was achieved using a charged aerosol detector (CAD).
- The results were compared quantitatively against the conventional fluorescent-labeled method using HILIC.
Main Results:
- The label-free method successfully detected and quantified N-glycans without fluorescent labeling.
- The developed method demonstrated significantly reduced sample preparation time and associated costs.
- Quantitative results obtained from the label-free method were comparable to those from the conventional fluorescent-labeled approach.
Conclusions:
- A novel, label-free method using mixed-mode PGC and CAD offers a streamlined and cost-effective alternative for N-glycan analysis of mAbs.
- This method is validated and suitable for routine use in biopharmaceutical product release testing.