Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Transcatheter Mitral Valve-in-Valve Replacement With Microaxial Flow-Pump Support for Bioprosthetic Valve Failure.

JACC. Case reports·2026
Same author

Transcatheter edge-to-edge mitral repair with a nitinol device in cardiogenic shock on micro-axial flow-pump support: a case report.

European heart journal. Case reports·2026
Same author

Leaflet Splitting to Prevent TAVR-Induced Coronary Obstruction in Stented vs Stentless Surgical Bioprosthetic Valves.

JACC. Cardiovascular interventions·2026
Same author

Timely hospital discharge in TAVI patients: towards a patient-centered care pathway.

Clinical research in cardiology : official journal of the German Cardiac Society·2026
Same author

Screening for amyloidosis before aortic valve elective replacement: results from the SAVER study.

European journal of preventive cardiology·2026
Same author

Impact of TAVR Failure Mechanism on Outcomes After Reintervention: From the EXPLANTORREDO-TAVR Registry.

Circulation. Cardiovascular interventions·2026

Related Experiment Video

Updated: Aug 24, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
06:59

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation

Published on: June 3, 2018

10.7K

Standard Transfemoral Transcatheter Aortic Valve Replacement.

Karel M Van Praet1,2, Gaik Nersesian1, Marian Kukucka3

  • 1Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany

Multimedia Manual of Cardiothoracic Surgery : MMCTS
|October 25, 2022
PubMed
Summary

Transcatheter aortic valve implantation (TAVI) is a revolutionary treatment for aortic valve disease, offering an effective alternative to surgery. Modern TAVI techniques improve outcomes and expand eligibility to lower-risk patients.

Keywords:
TranscatheterTransfemoral TAVI

More Related Videos

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
09:57

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement

Published on: January 20, 2022

2.7K
Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
08:50

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement

Published on: March 26, 2018

11.8K

Related Experiment Videos

Last Updated: Aug 24, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
06:59

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation

Published on: June 3, 2018

10.7K
Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
09:57

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement

Published on: January 20, 2022

2.7K
Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
08:50

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement

Published on: March 26, 2018

11.8K

Area of Science:

  • Cardiology
  • Interventional Cardiology
  • Medical Devices

Background:

  • Transcatheter aortic valve implantation (TAVI) has transformed aortic valve disease management.
  • Improvements in TAVI durability and techniques have expanded indications to younger, lower-risk patients.
  • TAVI is now a viable alternative to surgical aortic valve replacement for many patients.

Observation:

  • Contemporary TAVI focuses on optimizing outcomes and minimizing complications like paravalvular leakage and pacemaker implantation.
  • The procedure aims for a lifetime solution, ensuring secure coronary access and facilitating future valve-in-valve interventions.
  • This report details a standard transfemoral TAVI using a self-expandable supra-annular device.

Findings:

  • The transfemoral approach with a self-expandable supra-annular device is a common and effective TAVI method.
  • Ongoing advancements in TAVI technology continue to refine patient selection and procedural success.
  • The goal is to achieve durable valve function and reduce the need for reintervention.

Implications:

  • TAVI offers a less invasive option for aortic valve replacement, improving patient quality of life.
  • The expanding indications for TAVI suggest a shift towards less invasive cardiac procedures.
  • Future research will likely focus on long-term durability and further complication reduction.