Cardiorespiratory Fitness Estimation Based on Heart Rate and Body Acceleration in Adults With Cardiovascular Risk Factors: Validation Study
Related Experiment Video
Updated: Aug 24, 2025

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Antti-Pekka E Rissanen1,2,3, Mirva Rottensteiner1,4, Urho M Kujala4
1Central Finland Health Care District, Jyväskylä, Finland.
Insights
Wearable technology accurately estimates cardiorespiratory fitness (CRF) in adults with cardiovascular risks, with potential for clinical use. Accuracy was slightly lower in type 2 diabetes patients.
Area of Science:
- Cardiology
- Preventive Medicine
- Biomedical Engineering
Background:
- Cardiorespiratory fitness (CRF) is a critical predictor of cardiovascular health.
- Integrating CRF assessment into clinical practice can improve risk prediction.
- Wearable technologies offer a promising, yet under-validated, method for daily CRF estimation.
Purpose of the Study:
- To assess the accuracy of a wearable device in estimating CRF.
- To evaluate the device's validity in working-aged adults with cardiovascular risk factors.
Main Methods:
- 74 adults (35-64 years) with cardiovascular risk factors underwent a self-paced walk and a treadmill cardiopulmonary exercise test.
- CRF was estimated using a wearable ECG and acceleration device during the walk.
- Measured CRF (peak O2 uptake) was determined via ventilatory gas analysis during the treadmill test.
Main Results:
- The wearable device showed high accuracy in estimating CRF across all participants (mean difference -0.1 mL/kg/min, ICC 0.88).
- Subgroup analysis revealed similar accuracy, except for patients with type 2 diabetes who showed higher mean absolute error (4.2 mL/kg/min).
Conclusions:
- Wearable technology provides CRF estimates close to clinically significant levels in adults with cardiovascular risk factors.
- While generally accurate, the technology's performance in type 2 diabetes patients warrants further investigation.
- Wearable devices show potential for accurate, large-scale CRF estimation in clinical settings.
Background:
Cardiorespiratory fitness (CRF) is an independent risk factor for cardiovascular morbidity and mortality. Adding CRF to conventional risk factors (eg, smoking, hypertension, impaired glucose metabolism, and dyslipidemia) improves the prediction of an individual's risk for adverse health outcomes such as those related to cardiovascular disease. Consequently, it is recommended to determine CRF as part of individualized risk prediction. However, CRF is not determined routinely in everyday clinical practice. Wearable technologies provide a potential strategy to estimate CRF on a daily basis, and such technologies, which provide CRF estimates based on heart rate and body acceleration, have been developed. However, the validity of such technologies in estimating individual CRF in clinically relevant populations is poorly known.
Objective:
The objective of this study is to evaluate the validity of a wearable technology, which provides estimated CRF based on heart rate and body acceleration, in working-aged adults with cardiovascular risk factors.
Methods:
In total, 74 adults (age range 35-64 years; n=56, 76% were women; mean BMI 28.7, SD 4.6 kg/m2) with frequent cardiovascular risk factors (eg, n=64, 86% hypertension; n=18, 24% prediabetes; n=14, 19% type 2 diabetes; and n=51, 69% metabolic syndrome) performed a 30-minute self-paced walk on an indoor track and a cardiopulmonary exercise test on a treadmill. CRF, quantified as peak O2 uptake, was both estimated (self-paced walk: a wearable single-lead electrocardiogram device worn to record continuous beat-to-beat R-R intervals and triaxial body acceleration) and measured (cardiopulmonary exercise test: ventilatory gas analysis). The accuracy of the estimated CRF was evaluated against that of the measured CRF.
Results:
Measured CRF averaged 30.6 (SD 6.3; range 20.1-49.6) mL/kg/min. In all participants (74/74, 100%), mean difference between estimated and measured CRF was -0.1 mL/kg/min (P=.90), mean absolute error was 3.1 mL/kg/min (95% CI 2.6-3.7), mean absolute percentage error was 10.4% (95% CI 8.5-12.5), and intraclass correlation coefficient was 0.88 (95% CI 0.80-0.92). Similar accuracy was observed in various subgroups (sexes, age, BMI categories, hypertension, prediabetes, and metabolic syndrome). However, mean absolute error was 4.2 mL/kg/min (95% CI 2.6-6.1) and mean absolute percentage error was 16.5% (95% CI 8.6-24.4) in the subgroup of patients with type 2 diabetes (14/74, 19%).
Conclusions:
The error of the CRF estimate, provided by the wearable technology, was likely below or at least very close to the clinically significant level of 3.5 mL/kg/min in working-aged adults with cardiovascular risk factors, but not in the relatively small subgroup of patients with type 2 diabetes. From a large-scale clinical perspective, the findings suggest that wearable technologies have the potential to estimate individual CRF with acceptable accuracy in clinically relevant populations.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Cardiopulmonary Resuscitation I: Adult
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes

