Abstract:
Background: Most radial head prostheses were designed in Western countries based on the anatomical characteristics of Western populations. We hypothesised that these prostheses are too large for below-average height Thai women. The objective of this study is to evaluate the anthropometric parameters of the proximal radius in such a population and its correlation with commercially available prostheses. Methods: Dominant elbows of 124 Thai women whose height was <155 cm were studied. Using the standard anteroposterior and lateral radiographic images, the head diameter and thickness, the distance between the articular surface and radial tuberosity, the narrowest intra-medullary canal diameter and the narrowest outer diameter of the radial neck were measured. Correlations between body height and each radiographic parameter were assessed using the Pearson correlation coefficient (PCC). The specifications of the commercial metallic radial head implants were reviewed and used to evaluate the relevant radiographic parameters. Results: Mean of the minimum and maximum head diameter was 18.54 ± 1.11 mm and 19.13 ± 1.17 mm, respectively; the thickness was 7.43 ± 0.69 mm, the distance between the articular surface and tuberosity was 19.05 ± 1.45 mm, the intra-medullary canal diameter was 7.63 ± 1.2 mm and the outer diameter of the radial neck was 11.13 ± 1.26 mm. There is a poor correlation between the participant's height and each parameter (PCC ≤ 0.50). In 24.2% of the participants, the smallest size of prosthetic designs with a head diameter of 20 mm is larger than +2 mm in reference to minor diameter. The minimum prosthetic head thickness is greater than the average value of the participants in 12 out of 15 designs. One participant has an outer neck diameter smaller than the smallest stem diameter of three designs. Conclusions: Surgeons must be aware that commercially available radial head replacement implants may be too large for below-average height Thai women. Level of Evidence: Level IV (Prognostic).
More Related Videos
06:03Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: