Volume Analysis to Predict the Long-Term Evolution of Residual Aortic Dissection after Type A Repair
Marine Gaudry1, Carine Guivier-Curien2, Arnaud Blanchard1
1Timone Aortic Center, Department of Vascular Surgery, APHM, Timone Hospital, 13005 Marseille, France.
Abstract:
Background: The aim of this study was to evaluate the aortic diameter and volume during the first year after a type A repair to predict the long-term prognosis of a residual aortic dissection (RAD). Methods: All patients treated in our center for an acute type A dissection with a RAD and follow-up > 3 years were included. We defined two groups: group 1 with dissection-related events (defined as an aneurysmal evolution, distal reintervention, or aortic-related death) and group 2 without dissection-related events. The aortic diameters and volume analysis were evaluated on three postoperative CT scans: pre-discharge (T1), 3−6 months (T2) and 1 year (T3). Results: Between 2009 and 2016, 54 patients were included. Following a mean follow-up of 75.4 months (SD 31.5), the rate of dissection-related events was 62.9% (34/54). The total aortic diameters of the descending thoracic aorta were greater in group 1 at T1, T2 and T3, with greater diameters in the FL (p < 0.01). The aortic diameter evolution at 3 months was not predictive of long-term dissection-related events. The total thoracic aortic volume was significantly greater in group 1 at T1 (p < 0.01), T2 (p < 0.01), and T3 (p < 0.01). At 3 months, the increase in the FL volume was significantly greater in group 1 (p < 0.01) and was predictive for long-term dissection-related events. Conclusion: This study shows that an initial CT scan volume analysis coupled with another at 3 months is predictive for the long-term evolution in a RAD. Based on this finding, more aggressive treatment could be given at an earlier stage.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
07:42Author Spotlight: Enhanced Murine AAA Model Using Elastase to Mimic Human Aneurysms
Published on: July 26, 2024
Related Concept Videos
Aneurysm III: Interprofessional Care
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management
Aneurysm IV: Nursing Management