Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Canine mitral valve size as measured by computed tomography
Wanda J Gordon-Evans1, K Helena Montin1, Christopher P Ober2
1Veterinary Clinical Sciences Department, Veterinary Medical Center, University of Minnesota, St. Paul, MN.
Objective:
To measure the mitral annulus in dogs. Our hypothesis was that mitral measurement would be possible and consistent among observers using CT.
Sample:
Thoracic CT scans of dogs without known heart disease.
Procedures:
Five trained investigators measured 4 aspects of the mitral valve and the fourth thoracic vertebrae (T4) length using multiplanar reformatting tools. Ten randomly chosen animals were measured by all investigators to determine interobserver reliability.
Results:
There were 233 CT scans eligible for inclusion. Dogs weighed 2 to 96 kg (mean, 28.1 kg), with a variety of breeds represented. Golden Retrievers (n = 28) and Labrador Retrievers (n = 37) were overrepresented. The intraclass correlations were all greater than 0.9, showing excellent agreement between observers. The means and SDs of each measurement were as follows: trigone-to-trigone distance, 17.2 ± 4.7 mm; the remaining circumference, 79.0 ± 17.5 mm; commissure-to-commissure distance, 30.8 ± 6.5 mm; septal leaflet-to-lateral leaflet distance, 26.3 ± 6.0 mm; T4 length, 16.9 ± 3.1 mm; and the total circumference normalized by T4, 5.7 ± 0.7 mm.
Clinical Relevance:
This study provides information that may help in the development of future treatment for mitral valve dysfunction and subsequent annular enlargement.
More Related Videos
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
07:42An Image Guided Transapical Mitral Valve Leaflet Puncture Model of Controlled Volume Overload from Mitral Regurgitation in the Rat
Published on: May 19, 2020
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...