[Changes in the quality of vision after intrastromal allokeratoplasty for keratoconus (clinical observation)]
V M Sheludchenko1, Yu N Yusef1, G A Osipyan1
1Research Institute of Eye Diseases, Moscow, Russia.
Abstract:
Scleral lenses, corneal collagen crosslinking, corneal implants and deep anterior keratoplasty are used to correct deforming changes in the cornea at advanced stages of keratoconus, which improves the quality of vision (QoV). The article presents an analysis of changes in QoV in a 30-year-old patient with stage III keratoconus who underwent intracorneal implantation of an allograft with a width of 2.75 mm and thickness of 300 µm at a depth of 370 µm. The following parameters were measured before and 6 months after the procedure: uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), VA with glare, higher order aberrations (HOA), thickness of the lipid layer of the tear film, spatial contrast sensitivity, visual productivity. Observation results show that the Kmax index decreased from 55.9 D to 48.0 D, Kmin - from 39.8 D to 39.4 D, UCVA increased from 0.1 to 0.8 and BCVA - from 0.35 to 0.8. Thickness of the lipid layer of the tear film remained the same. The glare effect with different degrees of brightness did not affect visual acuity. Spatial contrast sensitivity in photopic conditions at medium frequencies increased from 19 to 37 dB, at high frequencies from - 0.5 to 22.5 dB, in mesopic conditions at medium frequencies from 11 to 28 dB, at high frequencies from - 0.5 to 12 dB. The «coma» and «spherical» aberrations decreased by 2 and 3 times, respectively, while «trefoil» increased by 3 times. Visual productivity increased by 36.8%. It may be concluded that the use of a wide intrastromal allograft in keratoconus improves the patient's visual quality and visual productivity. At the same time, the «vignetting» effect from the graft side is negligible in photopic conditions and is significant in mesopic conditions.
More Related Videos
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...