Related Experiment Video
Updated: Aug 23, 2025

A Generalized Method for Determining Free Soluble Phenolic Acid Composition and Antioxidant Capacity of Cereals and Legumes
Published on: June 10, 2022
The Novel Potentiometric Approach to Antioxidant Capacity Assay Based on the Reaction with Stable Radical
Elena Gerasimova1, Elena Gazizullina1, Sofya Kolbaczkaya1
1Analytical Chemistry Department, Institute of Chemical Engineering, Ural Federal University, 19 Mira Str., 620002 Ekaterinburg, Russia.
Abstract:
For the first time, new possibilities of using the DPPH• as a signal-forming oxidant molecule with potentiometric detection are shown. The CV method confirmed the presence of a quasi-reversible potential-determining system DPPH•/DPPH-H under experimental conditions. This fact makes it possible to use DPPH• as the model of the oxidizing agent for obtaining an analytical signal by the potentiometry method. The potentiometric approach makes it possible to obtain the value of the Nernst slope and the antioxidant capacity in one experiment. It consists of an antioxidant supplement and two consecutive DPPH• supplements. In this case, the calculation of the Nernst slope is carried out by introducing the second addition of the oxidizing agent and constructing a calibration curve against the reaction background with an antioxidant. Solutions of individual antioxidants α-tocopherol, quercetin, (±)-catechin hydrate, and α-lipoic acid were studied by the developed approach. A high correlation with the results of spectrophotometric measurements is shown. At the same time, the potentiometry method is devoid of the concentration limitations of the spectrophotometric method, which was confirmed. In the study of plant materials extracts, a high correlation of antioxidant capacity, obtained by potentiometric and spectrophotometric methods, was shown only for objects whose color did not contribute to the DPPH• absorption. The versatility of the potentiometric method for studying objects of any color was shown.
More Related Videos
08:57Simultaneous Measurement of Superoxide/Hydrogen Peroxide and NADH Production by Flavin-containing Mitochondrial Dehydrogenases
Published on: February 24, 2018
09:33Imaging Approaches to Assessments of Toxicological Oxidative Stress Using Genetically-encoded Fluorogenic Sensors
Published on: February 7, 2018
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Redox Titration: Overview