Published on: July 21, 2023
Dual-Energy CT for Accurate Discrimination of Intraperitoneal Hematoma and Intestinal Structures
Moritz T Winkelmann1, Florian Hagen1, Kerstin Artzner2
1Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, 72076 Tuebingen, Germany.
Abstract:
The purpose of this study was to evaluate the potential of dual-energy CT (DECT) with virtual unenhanced imaging (VNC) and iodine maps (IM) to differentiate between intraperitoneal hematomas (IH) and bowel structures (BS) compared to linearly blended DECT (DE-LB) images (equivalent to single-energy CT). This retrospective study included the DECT of 30 patients (mean age: 64.5 ± 15.1 years, 19 men) with intraperitoneal hematomas and 30 negative controls. VNC, IM, and DE-LB were calculated. Imaging follow-up and surgical reports were used as references. Three readers assessed diagnostic performance and confidence in distinguishing IH and BS for DE-LB, VNC, and IM. Diagnostic confidence was assessed on a five-point Likert scale. The mean values of VNC, IM, and DE-LB were compared with nonparametric tests. Diagnostic accuracy was assessed by calculating receiver operating characteristics (ROC). The results are reported as medians with interquartile ranges. Subjective image analysis showed higher diagnostic performance (sensitivity: 96.7−100% vs. 88.2−96.7%; specificity: 100% vs. 96.7−100%; p < 0.0001; ICC: 0.96−0.99) and confidence (Likert: 5; IRQ [5−5] vs. 4, IRQ [3−4; 4−5]; p < 0.0001; ICC: 0.80−0.96) for DECT compared to DE-LB. On objective image analysis, IM values for DECT showed significant differences between IH (3.9 HU; IQR [1.6, 8.0]) and BS (39.5 HU; IQR [29.2, 43.3]; p ≤ 0.0001). VNC analysis revealed a significantly higher attenuation of hematomas (50.5 HU; IQR [44.4, 59.4]) than BS (26.6 HU; IQR [22.8, 32.4]; p ≤ 0.0001). DE-LB revealed no significant differences between hematomas (60.5 HU, IQR [52.7, 63.9]) and BS (63.9 HU, IQR [58.0, 68.8]; p > 0.05). ROC analysis revealed the highest AUC values and sensitivity for IM (AUC = 100%; threshold by Youden-Index ≤ 19 HU) and VNC (0.93; ≥34.1 HU) compared to DE-LB (0.64; ≤63.8; p < 0.001). DECT is suitable for accurate discrimination between IH and BS by calculating iodine maps and VNC images.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...