Related Experiment Video
Updated: Aug 23, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Intermediate Crack Debonding of Externally Bonded FRP Reinforcement-Comparison of Methods
Paweł Tworzewski1, Jeffrey K Alexy2, Robert W Barnes3
1Department of Strength of Materials, Concrete and Bridge Structures, Kielce University of Technology, aleja Tysiąclecia Państwa Polskiego 7, 25-314 Kielce, Poland.
Abstract:
Many researchers around the world have made extensive efforts to study the phenomenon of fiber-reinforced polymer (FRP) debonding. Based on these efforts, code provisions and various models have been proposed for predicting intermediate crack (IC) debonding failure. The paper presents a comparison of seven selected models: fib bulletin 14 approach, Teng et al. model, Lu model, Seracino et al. model, Said and Wu model, Elsanadedy et al. model and ACI 440. The accuracy of each model was evaluated based on the test results of 58 flexural specimens with IC debonding failures of externally bonded (EB), carbon FRP plates or sheets found in the existing literature. The experimental database was prepared to include a wide range of parameters affecting the issue under consideration. A comparison of the measured and predicted load capacity values was made to evaluate the prediction accuracy of the considered models. The analysis included the limitation of the load capacity estimated based on IC debonding models as well as concrete crushing and FRP rupture types of failure. The results indicate that the latest models proposed for direct implementation in design guidelines-the Said and Wu model and the Elsanadedy et al. model-offer the best accuracy in predicting the load capacity. In contrast, the fib bulletin 14 approach shows a wide dispersion of predictions and a large proportion of highly overestimated results.
Related Concept Videos
Microcracking in Concrete
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Fiber Reinforced Concrete
Bonding and Strength of Aggregate