Optimization of Castor Oil-Based Ion Selective Electrode (ISE) with Active Agent 1,10-Phenanthroline for Aqueous Pb2+
Khairun Nisah1,2, Rahmi Rahmi3, Muliadi Ramli3
1Graduate School of Mathematics and Applied Sciences, Universitas Syiah Kuala, Banda Aceh 23111, Indonesia.
Abstract:
This research has successfully fabricated ion selective electrode (ISE) for Pb2+ using castor oil (Ricinus communis L.)-based polyurethane (PU) membrane with 1,10-phenanthroline as the active agent. The sensitivity of the Pb2+ ISE obtained is 27.25 mV/decade with a linear range of [Pb(NO3)2] of 10−10−10−5 M and a coefficient of determination (R2) of 0.959. The system response reaches stability after 25 s of measurement. The Pb2+ has a detection limit of 10−10 M and gives a stable response at pH 7−8 with a 15-day lifetime. The investigation of the selectivity of the ISE was performed using the mixed solution method with log Kij values of <1. The selectivity order of Pb2+ ISE against the foreign ions is Ag2+ > Ca2+ > K+ > Mg2+ > Cu2+ > Fe3+ > Cr3+> Zn2+ > Cd2+. The Pb2+ ISE shows acceptable reproducibility and repeatability with standard deviation values of 0.065 and 0.0079, respectively. Fourier transform infrared (FT-IR) spectra confirmed that 1,10-phenanthroline was responsible for the formation of the Pb2+ ion entrapment via complexation. Other characterizations (crystallinity, micro-surface morphology, and mechanical strength) suggest the degradation of the membrane structure integrity after the application. The analysis results of Pb levels using the Pb2+ ISE in artificial and wastewater samples were not significantly different from the atomic absorption spectroscopy (AAS) measurement.
Related Concept Videos
Extraction: Advanced Methods
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Electrodeposition
Electrodeposition can...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...