Related Experiment Video
Updated: Aug 23, 2025

Applications for Open Source Microplate-Compatible Illumination Panels
Published on: October 3, 2019
Assessment of the Performance of a Portable, Low-Cost and Open-Source Device for Luminance Mapping through a DIY
Francesco Salamone1,2, Sergio Sibilio1,2, Massimiliano Masullo2
1Construction Technologies Institute, National Research Council of Italy (ITC-CNR), Via Lombardia, 49, 20098 San Giuliano Milanese, MI, Italy.
Abstract:
Ubiquitous computing has enabled the proliferation of low-cost solutions for capturing information about the user's environment or biometric parameters. In this sense, the do-it-yourself (DIY) approach to build new low-cost systems or verify the correspondence of low-cost systems compared to professional devices allows the spread of application possibilities. Following this trend, the authors aim to present a complete DIY and replicable procedure to evaluate the performance of a low-cost video luminance meter consisting of a Raspberry Pi and a camera module. The method initially consists of designing and developing a LED panel and a light cube that serves as reference illuminance sources. The luminance distribution along the two reference light sources is determined using a Konica Minolta luminance meter. With this approach, it is possible to identify an area for each light source with an almost equal luminance value. By applying a frame that covers part of the panel and shows only the area with nearly homogeneous luminance values and applying the two systems in a dark space in front of the low-cost video luminance meter mounted on a professional reference camera photometer LMK mobile air, it is possible to check the discrepancy in luminance values between the low-cost and professional systems when pointing different homogeneous light sources. In doing so, we primarily consider the peripheral shading effect, better known as the vignetting effect. We then differentiate the correction factor S of the Radiance Pcomb function to better match the luminance values of the low-cost system to the professional device. We also introduce an algorithm to differentiate the S factor depending on the light source. In general, the DIY calibration process described in the paper is time-consuming. However, the subsequent applications in various real-life scenarios allow us to verify the satisfactory performance of the low-cost system in terms of luminance mapping and glare evaluation compared to a professional device.
More Related Videos
07:09Integrating Visual Psychophysical Assays within a Y-Maze to Isolate the Role that Visual Features Play in Navigational Decisions
Published on: May 2, 2019
07:12Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
Published on: April 11, 2025