Enhanced Modbus/TCP Security Protocol: Authentication and Authorization Functions Supported

Tiago Martins1, Sergio Vidal Garcia Oliveira1,2

  • 1Departamento de Engenharia Elétrica, Universidade do Estado de Santa Catarina, Joinville 89219-710, Brazil.

Summary

Human users pose the primary risk to operational technology (OT) security. This study enhances the Modbus/TCP Security protocol with authentication and authorization to prevent unauthorized access, ensuring OT network integrity.

Related Concept Videos

MOSFET: Enhancement Mode01:22

MOSFET: Enhancement Mode

Enhancement-mode MOSFETs are pivotal components in electronics, distinguished by their capacity to act as highly efficient switches. They are part of the larger family of metal-oxide Semiconductor Field-Effect Transistors (MOSFETs). They are available in two types: p-channel and n-channel, each tailored to specific polarity operations.
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
448
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
298
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
123
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
128
MOSFET: Depletion Mode01:20

MOSFET: Depletion Mode

Depletion-mode MOSFETs represent a unique subset of MOSFET technology, functioning fundamentally differently from their enhancement-mode counterparts. Unlike enhancement MOSFETs, which require a positive gate-source voltage (Vgs) to turn on, depletion-mode MOSFETs are inherently conductive and "normally on" devices.
The primary characteristic of depletion-mode MOSFETs is their ability to conduct current between the drain and source terminals without gate bias. This inherent conductivity...
450
IP3/DAG Signaling Pathway01:11

IP3/DAG Signaling Pathway

Membrane lipids such as phosphatidylinositol (PI) are precursors for several membrane-bound and soluble second messengers. Specific kinases phosphorylate PI and produce phosphorylated inositol phospholipids. One such inositol phospholipids are the  phosphatidylinositol-4,5 bisphosphate [PI(4,5)P2], present in the inner half of the lipid bilayer. Upon ligand binding, GPCR stimulates Gq proteins to turn on phospholipase Cꞵ. Activated phospholipase Cꞵ cleaves PI(4,5)P2 and...
12.3K