Wide-field tomography imaging of a double circuit using NV center ensembles in a diamond
Abstract:
The wide-field (2.42 mm × 1.36 mm, resolution: 5.04 µm) tomography imaging of double circuits is performed using nitrogen-vacancy (NV) center ensembles in a diamond. The magnetic-field distribution on the surface of the circuit produced by the lower layer is obtained. Vector magnetic superposition is used to separate the magnetic-field distribution produced by the lower layer from the magnetic-field distribution produced by two layers. An inversion model is used to perform the tomography imaging of the magnetic-field distribution on the lower layer surface. Compared with the measurements of the upper layer, the difference in the maximum magnetic-field intensity of inversion is approximately 0.4%, and the difference in the magnetic-field distribution of inversion is approximately 8%, where the depth of the lower layer is 0.32 mm. Simulations are conducted to prove the reliability of the imaging. These results provide a simple and highly accurate reference for the detection and fault diagnosis of multilayer and integrated circuits.
More Related Videos
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...