Related Experiment Video
Updated: Aug 23, 2025

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Does veno-arterial carbon dioxide gradient provide an adequate estimation of cardiac index in pulmonary hypertension?
Matthew T Siuba1, Abhishek Bhardwaj1, Jason Kirincich2
1Department of Critical Care Medicine, Respiratory Institute, Cleveland Clinic, 9500 Euclid Ave L2-330, Cleveland, OH 44195, USA.
Aims:
Pulmonary hypertension (PH) management is dependent on cardiac output (CO) assessment. The gold standard Fick method for CO and cardiac index (CI) measurement is not widely available. An accessible and reliable method for CO/CI estimation is needed not only in catheterization labs but also in other environments such as the intensive care unit, where pulmonary artery catheters are less likely to be used. We hypothesized that veno-arterial carbon dioxide gradient (PvaCO2) is a reliable surrogate for Fick CI in patients with PH.
Methods And Results:
A single-centre retrospective analysis of patients with PH who underwent direct Fick CI (DFCI) measurement during right heart catheterization. The primary outcome was correlation between PvaCO2 and DFCI. To assess the agreement between central and mixed venous CO2 values, a separate prospective cohort of patients was analysed. Data from 186 patients with all haemodynamic types of PH were analysed. PvaCO2 moderately correlated with Fick CI, R = -0.51 [95% confidence interval (CI): -0.61, -0.39]. A higher PvaCO2 was associated with an increased risk of CI < 2.5 L/min/m2 (odds ratio: 1.88, 95% CI: 1.55, 2.35). Low thermodilution CI with normal veno-arterial carbon dioxide gradient values was associated with a thermodilution underestimation of Fick CI. In the prospective analysis of 32 patients, central venous CO2 overestimated mixed venous values (mean difference 3.3, 95% CI: 2.5, 4.0) and there was poor agreement overall (limits of agreement -1.10, 7.59).
Conclusion:
Veno-arterial carbon dioxide gradient moderately correlates with Fick CI and may be useful to identify patients with low CI. Central and mixed venous CO2 values should not be used interchangeably in PH.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Cardiac Catheterization II: Right Heart Catheterization