Related Experiment Video
Updated: Aug 23, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Wear pattern-associated color stability of prefabricated composite veneers versus ceramic veneers
Marco Dederichs1, Stephanie Viebranz1, Hongseok An2
1Policlinic of Prosthetic Dentistry and Material Science, Centre for Dental Medicine, Jena University Hospital, Jena, Germany.
Purpose:
To evaluate the effect of different surface wear patterns on the discoloration tendency of two different prefabricated composite veneers and lithium disilicate ceramic veneers.
Materials And Methods:
Discoloration tendency of two prefabricated composite resin veneers (Visalys Veneer Chairside (VIS) and Componeer (COM)) were compared to lithium disilicate veneers (IPS) in vitro. For each material, n = 60 samples were allocated to different test groups, and therefore each n = 10 specimens per group went through different wear tests. Mechanical abrasion tests were conducted using a toothbrush simulator, while erosive effects were carried out by citric acid (pH 1.57). A combination of abrasion and erosion tests was conducted as well. Four groups of wear tests were implemented: (1) abrasion, (2) abrasion followed by erosion, (3) erosion, and (4) erosion followed by abrasion. Another group was stored in distilled water as the control and one group was stained without a prior wear test. The staining solution was made from a coffee-tobacco brew. Specimens were stored in the coffee-tobacco solution for 21 days. Color measurements were performed with VITA Easyshade. To evaluate intramaterial discoloration, one half of every specimen was protected with foil. After storage in the staining solution, the first measurement was carried out on the 'protected' (untreated) surface, followed by a second measurement on the 'processed' (treated) discolored surface. Euclidean distance (ΔE) of discoloration was calculated according to the CIE-L*C*h* system. Data were analyzed with ANOVA followed by Games-Howell post hoc test and paired t-test (α = 0.05).
Results:
Highest changes in ΔE were found in COM after 'abrasion' (ΔE -2.55) and 'erosion followed by abrasion' (ΔE -1.41). The discoloration tendency of VIS was affected by all wear tests, but changes were below the perceptive threshold (ΔE -0.19-0.32). Only abrasion followed by erosion affected the discoloration of IPS significantly, but findings were below the perceptive threshold, as well (ΔE -0.09).
Conclusions:
Prefabricated composite resin veneers revealed a low level of discoloration tendency after different wear tests. Nevertheless, in most cases the lowest discoloration tendency was found in specimens made from lithium disilicate.
More Related Videos
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
Related Concept Videos
Veneer
Other veneering techniques include plain-slicing, quarter-slicing, and rift-slicing. These...
Brick Durability, Strength, and Appearance
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Fineness of Cement
Direct...
Mortar