Related Experiment Video
Updated: Aug 23, 2025

Early Detection of Cyanobacterial Blooms and Associated Cyanotoxins using Fast Detection Strategy
Published on: February 25, 2021
A decision fusion method based on classification models for water quality monitoring
Mohamed Ladjal1, Mohamed Bouamar2, Youcef Brik2
1LASS, Laboratory of Analysis of Signals and Systems, Department of Electronics, Faculty of Technology, University of M'sila, M'sila, Algeria. mohamed.ladjal@univ-msila.dz.
Abstract:
Monitoring of water quality is one of the world's main intentions for countries. Classification techniques based on support vector machines (SVMs) and artificial neural network (ANN) has been widely used in several applications of water research. Water quality assessment with high accuracy and efficiency with innovational approaches permitted us to acquire additional knowledge and information to obtain an intelligent monitoring system. In this paper, we present the use of principal component analysis (PCA) combined with SVM and ANN with decision templates combination data fusion method. PCA was used for features selection from original database. The multi-layer perceptron network (MLP) and the one-against-all strategy for SVM method have been widely used. Decision templates are applied to increase the accuracy of the water quality classification. The specific classification approach was employed to assess the water quality of the Tilesdit dam in Algeria as a study area, defined with a dataset of eight physicochemical parameters collected in the period 2009-2018, such as temperature, pH, electrical conductivity, and turbidity. The selection of the excellent parameters of the used models can be improving the performance of classification process. In order to assess their results, an experiment step using collected dataset corresponding to the accuracy and running time of training and test phases, and robustness to noise, is carried out. Various scenarios are examined in comparative study to obtain the most results of decision step with and without feature selection of the input data. From the results, we found that the integration of SVM and ANN with PCA yields accuracy up than 98%. The combination by decision templates of two classifiers SVM and ANN with PCA yields an accuracy of 99.24% using k-fold cross-validation. The combination data fusion enhanced expressively the results of the proposed monitoring framework that had proven a considerable ability in surface water quality assessment.
Related Concept Videos
Testing Water Quality
Quality of Water
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Classification of Systems-I
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
Classification of Systems-II

