Observation of diffuse scattering in scanning helium microscopy.
S M Lambrick1, M Bergin2, D J Ward1
1Department of Physics, Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge, CB3 0HE, UK. sml59@cam.ac.uk.
Physical Chemistry Chemical Physics : PCCP
|October 28, 2022
Summary
Neutral helium microscopy reveals diffuse atom-surface scattering, approximately cosine-distributed, from native surfaces. This finding aids interpreting contrast in scanning helium microscopy (SHeM) images.
Area of Science:
- Surface science
- Microscopy
- Materials characterization
Background:
- Neutral helium microscopy (SHeM) is an emerging technique for surface analysis.
- Understanding atom-surface scattering is crucial for interpreting contrast in SHeM.
- Previous studies focused on pristine, atomically flat surfaces.
Purpose of the Study:
- To determine the atom-surface scattering distribution for native, unprepared surfaces in SHeM.
- To establish a baseline for interpreting contrast mechanisms in SHeM.
Main Methods:
- Experiments were conducted using a scanning helium microscope (SHeM).
- A range of sample surfaces were analyzed in their native state, without special preparation.
- Atom-surface scattering distributions were measured under typical operating conditions.
Main Results:
- Diffuse scattering was observed from native surfaces.
- The scattering distribution approximated a cosine function centered on the surface normal.
- This cosine-like distribution differs significantly from that observed on atomically pristine surfaces.
Conclusions:
- The study provides a typical scattering distribution for native surfaces in SHeM.
- This knowledge serves as a foundation for interpreting topographic contrast in SHeM images.
- It also offers a reference for comparing novel contrast mechanisms in neutral helium microscopy.
Related Concept Videos
Scanning Electron Microscopy
4.4K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.4K
Overview of Microscopy Techniques
10.7K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
10.7K