Related Experiment Video
Updated: Aug 23, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Quality by design-guided development of a capillary electrophoresis method for the chiral purity determination of
Adriana Modroiu1, Sulaiman Krait2, Gabriel Hancu3
1Friedrich Schiller University, Department of Pharmaceutical/Medicinal Chemistry, Philosophenweg 14, D-07743 Jena, Germany; George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, Department of Pharmaceutical and Therapeutic Chemistry, Faculty of Pharmacy, Gh. Marinescu 38, 540142 Târgu Mureș, Romania.
Abstract:
Silodosin is a single isomer selective α1-adrenoreceptor antagonist used for the treatment of benign prostatic hyperplasia. In order to control the enantiomeric purity of the drug a capillary electrophoresis method was developed that is applicable to the analysis of drug substance as well as pharmaceutical formulations. Method development followed a quality by design strategy. After selection of carboxymethyl-β-cyclodextrin as suitable chiral selector and the starting conditions in the scouting phase, a two-level full factorial design was applied to identify the critical process parameters. The final method optimization was performed using a face-centered central composite design resulting in the conditions 100 mM sodium phosphate buffer, pH 2.9, containing 40 mg/mL car-boxymethyl-β-cyclodextrin, a capillary temperature of 17 °C and an applied voltage of 28 kV. Robustness testing employing a Plackett-Burman design revealed the importance of careful pH adjustment in order to achieve suitable peak shape and resolution. The method was validated according to the guideline Q2(R1) of the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use and applied to the analysis of a commercial capsule formulation.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Electrophoresis: Overview
There...