Related Experiment Video
Updated: Aug 23, 2025

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
Premature monochorionic monoamniotic twins have lower lung compliance at birth than matched dichorionic diamniotic
Brian K Jordan1, Leah Bernard2, Sally Segel3
1Doernbecher Children's Hospital, Oregon Health & Science University, Portland, Oregon, USA.
Background:
Premature infants are born with immature lungs that demonstrate abnormal pulmonary function with differences in passive respiratory system compliance and resistance, and functional residual capacity. To our knowledge, no studies have evaluated differences in neonatal pulmonary function based on the type of twin gestation, or chorionicity. Given the effect of chorionicity on outcomes, we aimed to study the effect of twin type, monochorionic monoamniotic (MCMA) vs dichorionic diamniotic (DCDA), on neonatal early pulmonary function tests.
Methods:
In this prospective cohort study, 5 sets of DCDA twins were matched to 5 sets of MCMA twins on gestational age at delivery, latency from antenatal corticosteroid exposure, birthweight, race and gender. Mean values were compared for passive respiratory system compliance and resistance, functional residual capacity, and tidal volume.
Results:
MCMA infants had a significantly lower compliance (0.64 vs 1.25 mL/cm H2O /kg; p = 0.0001) and significantly higher resistance (0.130 vs 0.087 cm H2O /mL/sec; p = 0.0003) than DCDA infants. Functional residual capacity was lower for MCMA than DCDA infants (17.5 vs 23.4 mL/kg; p = 0.17). Further, 80% of MCMA infants required intubation for surfactant administration compared to 20% of DCDA infants, indicating the clinical significance of these objective measures.
Conclusions:
Due to the matched case-control design, causality cannot be established. However, we speculate that these differences in lung function may derive from differential exposure to preterm labor and endogenous maternal corticosteroid exposure. Further study is necessary to establish the true causal relationship.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Lung Capacity
Respiratory Volumes and Capacities I

