Related Experiment Video
Updated: Aug 23, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Comparison Between Continuous Positive Airway Pressure and High-Flow Nasal Cannula as Postextubation Respiratory
Catarina Martins1, Rita Pissarra2, Sandra Costa3
1Faculty of Medicine, University of Porto, Porto, Portugal.
Objective:
The interest in noninvasive respiratory support has been increasing, including continuous positive airway pressure and recent respiratory methods, namely high-flow nasal cannula. It is discussed if high-flow nasal cannula can reduce continuous positive airway pressure or invasive ventilation use. This systematic review and meta-analysis aimed to compare continuous positive airway pressure and high-flow nasal cannula as postextubation respiratory support in neonates.
Materials And Methods:
A literature search, based on Preferred Reporting of Items of Systematic Reviews and Meta-Analyses guidelines, was conducted across MEDLINE (through PubMed), Scopus, and Web of Science in 15 years (2006-2021) assessing randomized controlled trials that compared continuous positive airway pressure with high-flow nasal cannula as postextubation interventions in neonates. The primary outcome was extubation failure at 72 hours and/or at 7 days and the secondary outcomes included air leak syndrome, pneumothorax, bronchopulmonary dysplasia, nasal trauma, abdominal distension, and mortality.
Results:
Seven studies were included, comprising 1044 neonates. No statistically significant differences were found between high-flow nasal cannula and continuous positive airway pressure in extubation failure (at 72 hours and 7 days), air leak syndrome, pneumothorax, bronchopulmonary dysplasia, abdominal distension, and mortality. High-flow nasal cannula was associated with a lower incidence of nasal trauma (odds ratio = 0.21; 95% CI 0.08-0.52; P = .0008). Studies assessing extreme premature infants (<28 weeks) raised some efficacy and safety concerns.
Conclusion:
High-flow nasal cannula may be as effective and safe as continuous positive airway pressure, with similar extubation failure and risk of air leak syndrome, pneumothorax, bronchopulmonary dysplasia, abdominal distension, and mortality with the advantage of less nasal trauma. High-flow nasal cannula should be considered as an alternative to continuous positive airway pressure in postextubation settings in neonates. Further studies are needed to establish efficacy and safety in lower gestational ages.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Suctioning the Nasopharyngeal Airway
Equipment Required
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...