Related Experiment Video
Updated: Aug 23, 2025

Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
Cervical spine movements during laryngoscopy and orotracheal intubation: a systematic review and meta-analysis
Jaqueline Betina Broenstrup Correa1, Vinicius Brenner Felice1, Graciele Sbruzzi1
1Programa de Pós-graduação em Ciências Pneumológicas, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil.
Background:
Airway management is challenging in trauma patients because of the fear of worsening cervical spinal cord damage. Video-integrated and optic-integrated devices and intubation laryngeal mask airways have been proposed as alternatives to direct laryngoscopy with the Macintosh laryngoscope (MAC). We performed a meta-analysis to clarify which devices cause less cervical movement during airway management.
Methods:
We searched MEDLINE, Cochrane Central, Embase and LILACS from inception to January 2022. We selected randomised controlled trials comparing alternative devices with the MAC for cervical movement from C0 to C5 in adult patients, evaluated by radiological examination. Additionally, cervical spine immobilisation (CSI) techniques were evaluated. We used the Cochrane Risk of Bias Tool to evaluate the risk of bias, and the principles of the Grading of Recommendations, Assessment, Development, and Evaluations system to assess the quality of the body of evidence.
Results:
Twenty-one studies (530 patients) were included. Alternative devices caused statistically significantly less cervical movement than MAC during laryngoscopy with mean differences of -3.43 (95% CI -4.93 to -1.92) at C0-C1, -3.19 (-4.04 to -2.35) at C1-C2, -1.35 (-2.19 to -0.51) at C2-C3, and -2.61 (-3.62 to -1.60) at C3-C4; and during intubation: -3.60 (-5.08 to -2.12) at C0-C1, -2.38 (-3.17 to -1.58) at C1-C2, -1.20 (-2.09 to -0.31) at C2-C3. The Airtraq and the Intubation Laryngeal Mask Airway caused statistically significant less movement than MAC restricted to some cervical segments, as well as CSI. Heterogeneity was low to moderate in most results. The quality of the body of evidence was 'low' and 'very low'.
Conclusions:
Compared with the MAC, alternative devices caused less movement during laryngoscopy (C0-C4) and intubation (C0-C3). Due to the high risk of bias and the very low grade of evidence of the studies, further research is necessary to clarify the benefit of each device and to determine the efficacy of cervical immobilisation during airway management.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...

