Comparison of bilateral eardrum temperatures measured using an infrared tympanic thermometer before and after surgery in patients with chronic otitis media
Related Experiment Video
Updated: Aug 23, 2025

Endaural Endoscopic Atticoantrotomy Retrograde Mastoidectomy using a Constant Suction Bone-drilling Technique
Published on: May 23, 2021
1Department of Otorhinolaryngology-Head & Neck Surgery, Daegu Catholic University School of Medicine, Daegu, Republic of Korea.
Abstract:
This study aimed to investigate the effect of chronic otitis media (COM) and COM surgery on infrared tympanic thermometer measurements. We retrospectively reviewed the medical records of 192 patients (192 surgery cases) who underwent surgery for COM and whose bilateral tympanic membrane temperature was measured with an infrared tympanic thermometer the day before surgery and at 2, 3, 4, and 6 months after surgery. Patients underwent surgery for COM in 1 ear, the other eardrum was intact. Patients who underwent tympanoplasty, simple mastoidectomy, and canal wall up mastoidectomy, surgeries performed to preserve the ear canal, were included in group A, and patients who underwent canal wall down mastoidectomy, a surgery to remove the ear canal, were included in group B. There were 115 and 77 patients in groups A and B, respectively. The mean temperature on the side with COM measured the day before surgery was 37.09°C ± 0.325°C and the mean temperature on the opposite normal side was 37.03°C ± 0.330°C (P = .000). In group A, the eardrum temperature on the surgical and contralateral side was not statistically different after surgery (P = .439). The temperature difference between both sides of the eardrums (dTemp) changed from 0.056°C before surgery to 0.014°C after surgery (P = .008). However, in group B, which canal wall down mastoidectomy was performed, the eardrum temperature of the surgical side was higher than that on the other side (P = .001). The dTemp increased up to 0.15°C after surgery (P = .000). The temperature of the eardrum was slightly increased by COM. The COM surgeries, which preserve the ear canal, brought the temperature of the eardrum close to that of the normal eardrum, and the surgery to remove the ear canal raised the temperature of the eardrum.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...