Dose Assessment Following a 238 Pu Inhalation Incident at Los Alamos National Laboratory
Deepesh Poudel1, Sara Dumit1, Luiz Bertelli1
1Radiation Protection Services, Los Alamos National Laboratory, Los Alamos, NM.
Abstract:
A glovebox breach at the plutonium facility at Los Alamos National Laboratory potentially exposed 15 individuals to 238 Pu aerosols. One of the individuals (P0) received two 1-g intravenous DTPA treatments, one on the day of the intake and another the following day. Several urine samples were collected from the individuals involved in the incident. Particle size analysis on the PPE and solubility analysis of the particles on a filter sample were conducted in vitro. The applicability of the results from the in vitro studies for dose assessment was questionable because of the effect of the cloth mask the workers were wearing for COVID-related protection. Based on several considerations, including the effect of cloth masks on the "effective" particle size inhaled and the analysis of fecal-to-urine ratio, the default Type M 1 μm AMAD model was used to estimate intakes and doses. Using the urinary excretion data collected after 100 d post last chelation treatment, the committed effective dose, E(50), for P0 was calculated to be 5.2 mSv. For all others, the bioassay data were consistent with no intakes or very small intakes [corresponding to E(50) less than 0.1 mSv].