Balloon-Expandable TAVR Bioprostheses: Area or Perimeter Sizing? A Prospective Pilot Study
Jonathan Halim1, Peter den Heijer1, Jeroen Vos1
1Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK, Breda, Netherlands.
Perimeter sizing for balloon-expandable valves in transcatheter aortic valve replacement (TAVR) resulted in larger valve selection and favorable outcomes. This approach may improve safety and efficacy compared to traditional area sizing.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Medical Device Technology
Background:
- Current transcatheter aortic valve replacement (TAVR) practices utilize area sizing for balloon-expandable (BE) valves, despite their circular frame potentially mismatching elliptical annuli.
- This discrepancy may lead to relative undersizing and suboptimal clinical outcomes for BE valves.
- Self-expanding valves are sized using annulus perimeter, suggesting a potential benefit for perimeter-based sizing in BE valves.
Purpose of the Study:
- To develop and evaluate a perimeter-based sizing algorithm for the Myval BE valve.
- To assess the safety and feasibility of perimeter sizing in patients undergoing TAVR with the Myval BE valve.
Main Methods:
- A prospective, single-center study included 60 patients with severe aortic stenosis treated with the Myval BE valve.
- Perimeter sizing was employed with a limited oversizing margin of 3.7% ± 1.3% relative to the annulus perimeter.
- Clinical outcomes were assessed at 30 days and 1 year post-TAVR, with echocardiographic follow-up at 30 days.
Main Results:
- At 30 days, pacemaker implantation (PPI) and stroke rates were 2% and 3%, respectively. No moderate-severe paravalvular leak (PVL) or cardiac death occurred.
- At 1 year, cardiac death and stroke rates were 3% and 8%, respectively.
- A larger valve size was implanted in 33.3% of patients compared to area sizing calculations.
Conclusions:
- Perimeter sizing with the Myval BE valve facilitated the use of larger valve sizes and demonstrated favorable clinical outcomes, including low PPI and no significant PVL.
- This alternative sizing method shows promise for improving TAVR procedures with BE valves.
- A randomized controlled trial is planned to confirm the superiority of perimeter sizing.