Agreement between standard and continuous wireless vital sign measurements after major abdominal surgery: a clinical
Camilla Haahr-Raunkjaer1,2, Magnus Skovbye1, Søren M Rasmussen3
1Department of Anesthesiology, Center for Cancer and Organ Diseases, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Abstract:
Objective. Continuous wireless monitoring outside the post-anesthesia or intensive care units may enable early detection of patient deterioration, but good accuracy of measurements is required. We aimed to assess the agreement between vital signs recorded by standard and novel wireless devices in postoperative patients.Approach. In 20 patients admitted to the post-anesthesia care unit, we compared heart rate (HR), respiratory rate (RR), peripheral oxygen saturation (SpO2), and systolic and diastolic blood pressure (SBP and DBP) as paired data. The primary outcome measure was the agreement between standard wired and wireless monitoring, assessed by mean bias and 95% limits of agreement (LoA). LoA was considered acceptable for HR and PR, if within ±5 beats min-1(bpm), while RR, SpO2, and BP were deemed acceptable if within ±3 breaths min-1(brpm), ±3%-points, and ±10 mmHg, respectively.Main results.The mean bias between standard versus wireless monitoring was -0.85 bpm (LoA -6.2 to 4.5 bpm) for HR, -1.3 mmHg (LoA -19 to 17 mmHg) for standard versus wireless SBP, 2.9 mmHg (LoA -17 to 22) for standard versus wireless DBP, and 1.7% (LoA -1.4 mmHg to 4.8 mmHg) for SpO2, comparing standard versus wireless monitoring. The mean bias of arterial blood gas analysis versus wireless SpO2measurements was 0.02% (LoA -0.02% to 0.06%), while the mean bias of direct observation of RR compared to wireless measurements was 0.0 brpm (LoA -2.6 brpm to 2.6 brpm). 80% of all values compared were within predefined clinical limits.Significance.The agreement between wired and wireless HR, RR, and PR recordings in postoperative patients was acceptable, whereas the agreement for SpO2recordings (standard versus wireless) was borderline. Standard wired and wireless BP measurements may be used interchangeably in the clinical setting.
More Related Videos
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
07:14A Quantitative Sensory Testing Paradigm to Obtain Measures of Pain Processing in Patients Undergoing Breast Cancer Surgery
Published on: January 18, 2018
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Aneurysm IV: Nursing Management