Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Speeding up temperature-responsive × reversed-phase comprehensive liquid chromatography through the combined
Kristina Wicht1, Mathijs Baert1, Norwin von Doehren2
1Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, Ghent B-9000, Belgium.
Abstract:
Comprehensive two-dimensional liquid chromatography (LC×LC) can provide enhanced resolving power and higher peak capacities for the separation of complex samples. The transfer of fractions of too high eluotropic strength from the first dimension, however, can lead to peak broadening. This process is related to the column dimensions, the flow rates, mobile phase compositions, and stationary phase compatibility. Temperature-responsive LC (TRLC) uses a smart polymer coupled to silica (poly(N-isopropylacrylamide), pNIPAAm), that exhibits a change in polarity upon modest variations in column temperature. Retention is thus modulated by temperature and not by organic solvents, allowing for the use of purely aqueous mobile phases. As these aqueous mobile phases depict a very low eluotropic strength on a reversed-phase column, it facilitates band refocusing at the second-dimension column head in TRLC×RPLC. One of the remaining obstacles of TRLC is the long analysis time. In this research, the potential of this column combination in terms of analyte refocusing will be exploited. First, it is shown that upwards flow gradients can be implemented in the first dimension of TRLC×RPLC. As the flow in the second dimension is maintained at a constant level, a first-dimension flow gradient does not lead to impaired sensitivity and has no negative effects on the resulting peak size. Then, the novel combination of a downwards temperature gradient with an upwards flow gradient will be introduced to speed up the analyses further. Analysis time was, depending on the method used, reduced by 36-54%, as demonstrated by the analysis of mixtures of food additives, phenolic compounds, and small molecule pharmaceuticals mimicking impurity analysis at a 0.05% level.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...