Insights
The use of non-drug-eluting devices in percutaneous coronary intervention (PCI) significantly decreased in the U.S. from 2016-2019. These devices were often used in older patients with high bleeding risk, but suboptimal outcomes highlight a need for better treatment options.
Area of Science:
- Cardiology
- Interventional Cardiology
- Health Services Research
Background:
- Contemporary data on non-drug-eluting devices in percutaneous coronary intervention (PCI) in the U.S. is limited.
- Non-drug-eluting devices include balloon angioplasty and bare-metal stents.
Purpose of the Study:
- To analyze trends in the utilization of non-drug-eluting devices for PCI in the United States from 2016 to 2019.
- To identify patient characteristics and outcomes associated with the use of these devices.
Main Methods:
- Utilized the Nationwide Readmissions Database to identify patients undergoing PCI with non-drug-eluting devices between 2016 and 2019.
- Analyzed trends in device utilization, patient demographics, indications for use, and in-hospital outcomes.
Main Results:
- Non-drug-eluting devices accounted for 6.8% of 1,870,262 PCI procedures.
- Utilization decreased from 12.9% in Q1 2016 to 3.4% in Q4 2019 (p <0.001).
- Associated factors included advanced age and high bleeding risk; 72% were used for acute myocardial infarction (MI), with 18% experiencing reinfarction within 30 days.
Conclusions:
- The use of non-drug-eluting devices in PCI has declined significantly in the U.S.
- These devices are predominantly used in elderly patients with high bleeding risk.
- Suboptimal outcomes underscore an unmet clinical need for alternative PCI treatment options.
Abstract:
There is a paucity of data on the contemporary use of non-drug-eluting devices (balloon angioplasty or bare-metal stents) in contemporary percutaneous coronary intervention (PCI) in the United States. We utilized the Nationwide Readmissions Database to identify patients hospitalized to undergo PCI with non-drug-eluting devices from 2016 to 2019. The main outcome of interest was the trends in utilization over the study years. Among 1,870,262 PCI procedures, 127,810 (6.8%) were performed with non-drug-eluting devices; 72% of these were in the setting of acute myocardial infarction (MI). The use of non-drug-eluting devices decreased throughout the study period from 12.9% of all PCI in the first quarter of 2016 to 3.4% in the last quarter of 2019 (p <0.001). Factors associated with their use included advanced age and high bleeding risk. Only a small percentage were used as a bridge to coronary artery bypass graft surgery (2%) and for treatment of in-stent restenosis (3%). The in-hospital mortality was 5.8% for the entire cohort and 6.6% when the indication for use was an acute MI. In patients presenting with an acute MI, reinfarction within 30 days was common and occurred in 18% of the patients. In conclusion, the use of non-drug-eluting devices in PCI in the United States decreased from 2016 to 2019. Factors associated with their use included old age and high bleeding risk. Due to suboptimal outcomes in patients currently being treated with non-drug-eluting devices, there remains an unmet clinical need for alternative treatment options.
More Related Videos
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Acute Coronary Syndrome IV: Interprofessional Care
Coronary Artery Disease V: Interprofessional Care
Peripheral Artery Disease III: Interprofessional Care
Cardiac Catheterization IV: Nursing Management
Angina IV: Management