Imaging a microfocus X-ray focal spot with a thin coded aperture
Graham R Davis1, Thomas Beckenbach2, Pascal Meyer3
1Institute of Dentistry, Queen Mary University of London, London, E1 4NS, UK. g.r.davis@qmul.ac.uk.
Abstract:
Imaging of the focal spot size in X-ray generators can be achieved by means of a pinhole in a highly attenuating material, such as gold. For microfocus generators with spot sizes of only around 10 microns or less, the material must be very thin to avoid an impractical aspect ratio. With a 90 kV source, only 11% attenuation is attained with 5 µm gold. For a pinhole that is smaller than the focal spot, the signal-to-noise ratio (SNR) may be less than 1. To image the focal spot of a medical X-ray generator, a coded aperture has been used previously to reduce the exposure time required, however the same technique does not appear to have been used to increase the SNR when the attenuation is very low. Such a method is used here, using a no-two-holes-touching variation of a modified uniformly redundant array (MURA). In a prototype sample, with only 5 µm gold having 2.75 µm holes, the focal spot of a microfocus X-ray generator used in a micro-CT system could be clearly visualised and quantified. Directionality of the aberrations made focussing of the X-ray spot more intuitive and reduced the time required to obtain an optimal, quantifiable focus.
Related Concept Videos
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Confocal Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...